Text excerpt from page 67 (click to view)
Adjusting the White Balance/Black Balance
The black balance must be adjusted in the following cases. �When the unit is used for the first time �When the unit is first used after an extended period of non-use �When the unit is used under conditions where the ambient temperature has changed by a wide margin �When the gain selector value is changed �When the SUPER IRIS button setting is changed (when setting is changed to o30 dB) �When the gamma ON/OFF is changed
Adjusting the Black Balance
1
Set the switches as shown in the figure.
MENU SET/OFF: OFF
OUTPUT: CAM
2
Press the AUTO W/B BAL switch to the ABB side and then release the switch. The switch returns to the center and the black balance is automatically adjusted.
AUTO W/B BAL switch
3
During the adjustment, the following message will appear on the viewfinder screen. (However, the message appears only when the display mode is set to �2� or �3�.)
ABB ACT I VE
Message during adjustment
�The lens iris automatically goes to the �CLOSE� position during the adjustment.