Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 446 guests and 
2 members online.
Categories
Information
Featured Product
Home >> PANASONIC >> CSA241KR Service Manual
 
 0 item(s) in your cart 

PANASONIC CSA241KR
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of PANASONIC CSA241KR Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages:

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 ZSX5000 SONY Service Manual by Diogo Silva;
You can fully trust on this one! All the schematics are very crear an in one piece per page
 Z-5000 TEAC Service Manual by MESUT BALCI;
I have never bought a service manual which is as competely readable as this althogh it was a scanned pdf. Thank you for this succesful manual also cheaper than other sites.
 T-77 SANSUI Service Manual by Åsbjörn Ulvstig;
Thanks for a very good and readable servicemanual. Just what I needed as a "dinosaur technician". I really recommmend this site and will come back. Åsbjörn
 VT6500A HITACHI Service Manual by Virgil Norman;
The manual I purchased was just what I needed. I was glad to find a site where I can find so many manuals on a wide variety of products.
 LT-37X776/KA JVC Service Manual by Arthur Costa;
The best diagram that I used in a long time. Everything was right on te money. It was easy and fast. Iwoiuld but again when I need a service manual.

Text excerpt from page 27 (click to view)
CS-A181KR

1 Evacuation of Installation
When installing an air conditioner, be sure to evacuate the air inside the indoor unit and pipes in the following procedure. Required tools: hexagonal wrench, adjustable wrench, torque wrenches, wrench to hold the joints, gas leak detector, and charging set.
(Indoor unit) (Liquid side) 3-way valve Close

The air in the indoor unit and in the piping must be purged. If air remains in the refrigeration pipings, it will affect the compressor, reduce the cooling capacity, and could lead to a malfunction.

(Outdoor unit)

(Gas side)

3-way valve OPEN Close Vacuum pump
Lo Hi

OPEN

Service port cap Be sure, using a torque wrench to tighten the service port cap (after using the service port), so that it prevents the gas leakage from the refrigeration cycle.

Procedure:
(1) Connect a charging hose with a push pin to the Low and High sides of a charging set and the service ports of a 3-way valves. q Be sure to connect the end of the charging hose with the push pin to the service port. (2) Connect the centre hose of the charging set to a vacuum pump. (3) Turn on the power switch of the vacuum pump and make sure that the needle in the gauge moves from 0 cmHg (0 MPa) to â76 cmHg (â0.1 MPa). Then evacuate the air for approximately 10 minutes. (4) Close the valve of both the Low and High sides of the charging set and turn off the vacuum pump. Make sure that the needle in the gauge does not move after approximately 5 minutes. BE SURE TO TAKE THIS PROCEDURE IN ORDER TO AVOID REFRIGERANT GAS LEAKAGE. (5) Disconnect the charging hose from the vacuum pump and from the service ports of the 3-way valves.
â 26 â

(6) Tighten the service port caps of both the 3-way valves at a torque of 18 Nâ¢m with a torque wrench. (7) Remove the valve caps of both the 3-way valves. Position both of the valves to âopenâ using a hexagonal wrench (4 mm). (8) Mount valve caps onto both of the 3-way valves. q Be sure to check for gas leakage.

Caution
If gauge needle does not move from 0 cmHg (0 MPa) to â76 cmHg (â0.1 MPa) in step (3) above, take the following measures: If the leaks stop when the piping connections are tightened further, continue working from step (3). If the leaks do not stop when the connections are retightened, repair the location of the leak.

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG-7500 PANASONIC
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

YB400PE GRUNDIG
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

CJ-V51 PIONEER
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
>
Parse Time: 0.159 - Number of Queries: 132 - Query Time: 0.032