The service manual is scanned, but high quality, high resolution. The smallest texts on schematics diagram is readable. Super! Thank you!
Text excerpt from page 122 (click to view)
an upper limit of 31°C and a lower limit of 16°C.)
1. While operation is stopped, press the TEMP UP and TEMP DOWN buttons simultaneously.
2. To set an upper limit Press the OPERATION button until HEAT is displayed. / / Press the TEMP UP or TEMP DOWN button to set the temperature. / / Press the SET button to complete the upper limit setting. / Example: / If the heating display is set to 28°C, setting the temperature to higher than 28°C will not be possible. / * Upper and lower limits cannot be set at the same time. 3. To set a lower limit Press the OPERATION button until COOL is displayed. / / Press the TEMP UP or TEMP DOWN button to set the temperature. / / Press the SET button to complete the lower limit setting. / Example: / If the cooling display is set to 22°C, setting the temperature to lower than 22°C will not be possible. / * Press the CANCEL button to cancel the setting. 23.2. Switching to the remote control thermistor - The temperature detection thermistor used for detecting the indoor temperature can be switched between the thermistor at the indoor