Awesome quality manual. You really saved my bacon with this one. Was looking for some specific information with regards to my "new" vintage VCR that didn't come with the owners manual. This site is truely a goldmine of available manuals. The quality of the scans are top notch.
Thank-you so much for this awesome manual. If you're looking for this Sony SL-HF400 owners manual, this is the one you NEED to buy. Definitely worth the money.
The manual was made available promptly. I is a clean scan of the original. I had no problem downloading it. The scan was well centered and cleanly formatted. It is as good a product as can be had without being the original document.
Received downlink in less then 8 hours, Item was in good copy condition, and told me how to program the clock timer. The price was very resonable, and the process was very automated and was GREAT to work with.
I was very pleased with the manual I got for my amateur (ham) radio. Without it I could not figure out how to input and/or change the P/L setting on my radio. It drove me nuts as the radio was essentially useless. That all changed when my manual came. Then it took only minutes and I was done. Now my radio works fine. This is an exceptionally good resource as it's a very easy and user friendly download. Thank you very much! Dziękujemy za!
Text excerpt from page 15 (click to view)
Before you call for service...
Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service.
Normal Operation
� You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. � You may hear the relay click when the compressor cycles on and off. � Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit. � The fan may run even when the compressor does not.
Abnormal Operation
Problem Possible Causes s The air conditioner is unplugged.
Air conditioner does not start
What To Do � Make sure the air conditioner plug is pushed completely into the outlet. � Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. � When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. � Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner. � Set the TEMP Control to a lower number. � Clean the filter at least every 2 weeks. See the operating instructions section. � When the air conditioner is first turned on you need to allow time for the room to cool down. � Check for open furnace floor registers and cold air returns. � Set the air conditioner's vent to the closed position. � See Air Conditioner Freezing Up below. � Set the mode control at High Fan or High Cool with the high temperature.
s The fuse is blown/circuit breaker is tripped. s Power failure.
s Airflow is restricted. s TEMP Control set to a higher number.
Air conditioner does not cool as it should
s The air filter is dirty. s The room may have been hot. s Cold air is escaping.
Before you call for service...
s Cooling coils have iced up.
Air conditioner freezing up
s Ice blocks the air flow and stops the air conditioner from cooling the room.