Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
Text excerpt from page 10 (click to view)
3.4.2.
INITIAL SETTINGS:
When you replace the Main PCB, be sure to perform the initial settings after achieving the adjustment by ordering the following procedure in accordance with model suffix of the unit. 1. IMPORTANT NOTICE: Before proceeding Initial settings, be sure to read the following CAUTIONS.
2. PROCEDURES: � Preparation. Proceed the picture back up from the unit (Refer to above "CAUTION 2") � Step 1. The temporary cancellation of initial setting: Set the mode dial to �[ Normal picture mode ] (Red camera mark)�. While keep pressing [E.ZOOM ] and �[ UP ] of Cross key� simultaneously, turn the Power on. � Step 2. The cancellation of initial setting: Set the mode dial to �[ Playback ]�. Press [E.ZOOM ] and �[ UP ] of Cross key� simultaneously, then turn the Power off. � Step 3. Turn the Power on: Set the mode dial to �[ Normal picture mode ] (Red camera mark)�, and then turn the Power on. � Step 4. Display the INITIAL SETTING: While keep pressing [ MENU ] and �[ RIGHT ] of Cross key� simultaneously, turn the Power off.