3.4.2.
INITIAL SETTINGS:
When you replace the Main PCB, be sure to perform the initial settings after achieving the adjustment by ordering the following procedure in accordance with model suffix of the unit. 1. IMPORTANT NOTICE: Before proceeding Initial settings, be sure to read the following CAUTIONS.
2. PROCEDURES: � Preparation. Proceed the picture back up from the unit (Refer to above "CAUTION 2") � Step 1. The temporary cancellation of factory setting: Set the mode dial to �[ Normal picture mode ] (Red camera mark)�. While keep pressing [ Optical Image Stabilizer ] and �[ UP ] of Cross key� simultaneously, turn the Power on. � Step 2. The cancellation of factory setting: Set the mode dial to �[ Playback ]�. Press [ Optical Image Stabilizer ] and �[ UP ] of Cross key� simultaneously, then turn the Power off. � Step 3. Turn the Power on: Set the mode dial to �[ Normal picture mode ] (Red camera mark)�, and then turn the Power on. � Step 4. Display the INITIAL SETTING: While keep pressing [ MENU ] and �[ RIGHT ] of Cross key� simultaneously, turn the Power off.
10
|
|
|
> |
|