KX-P7105 / KX-P7110
3.13.4. Thermostat
(1) (2) Remove the 2 screw ( A ) and Thermal Fuse. Remove the screw ( B ) and Thermostat.
Caution : · When reinstalling the thermostat, both end terminals must be positioned under the terminals of thermal fuse and lead wire as shown in the following figure, or thermostat cannot properly measure the surface temperature of the heat roller becausethe distance between the surface of heat roller and thermostat may change. · When reinstalling the thermal fuse and thermostat, the screws must be tightened in order (1), (2), (3) to position them correctly as shown in the following figure.