Shopping cart is empty
English Polski Spanish 
Search For a Manual

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
Who's Online
There currently are 278 guests online.
Featured Product
Home >> PANASONIC >> NNS763BF Service Manual
 0 item(s) in your cart 

Service Manual

Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of PANASONIC NNS763BF Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages:

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 DD-VR9/U JVC Service Manual by Dmitry Khazov;
Very good scanned copies. Quick response and reasonable price. Thanks for service!
 DCX4000L SANYO Service Manual by Daniel Kubala;
Good. Good. Good. Good. Good. Good. Good. Good. Good. Good. Good. Good. Good. Good.
 PD-M450 PIONEER Service Manual by Tim Warner;
Very helpfull information and I highly recommend this source for needed information about your products.
 MHC-1750 SONY Service Manual by Gerald Fudge;
More than pleased with my prurchase, very good product for the price.
 KR-V55R KENWOOD Service Manual by Joseph Souza;
This is a good quality scan of the service manual which includes an assembly diagram, block diagram, schematic, and parts list. Exactly what is needed to repair my KR-V55R receiver.

Text excerpt from page 8 (click to view)
NN-T793SF / NN-T783SF / NN-T763SF / NN-S763BF / NN-S763WF / NN-S753BF / NN-S753WF / NN-S743BF / NN-S743WF

4.2.1. Measurement with the outer panel removed.
Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed and after all necessary components are replaced or adjusted. Special care should be taken in measuring around the magnetron.

NOTE: The U.S. Government standard is 5 mW/cm 2 while in the customer’s home. 2mW/cm 2 stated here is our own voluntary standard. (1mW/cm2 for Canada)


Measurements with a fully assembled oven.



After all components, including outer panel are fully assembled, measure for radiation leakage around the door periphery, the door viewing window, the exhaust opening and air inlet openings.

• Electromagnatic radiation monitor • 600cc glass beaker

• Glass thermometer 212°F or 100°C


Record keeping and notification after measurement


Procedure for measuring radiation leakage

• After any adjustment or repair to a microwave oven, a leakage reading must be taken. Record this leakage reading on the repair ticket even if it is zero. A copy of this repair ticket and the microwave leakage reading should be kept by repair facility. • Should the radiation leakage be more than 2 mW/cm2 (1mW/cm for Canada) after determining that all parts are in good condition, functioning properly, and genuine replacement parts as listed in this manual have been used, immediately notify PASC, PSC or PCI.

Note before measuring. • Do not exceed meter full scale deflection. Leakage monitor • should initially be set to the highest scale. • To prevent false readings the test probe should be held by the grip portion of the handle only and moved along the shaded area in Figure no faster than 1 inch/sec (2.5cm/sec). • Leakage with the outer panel removed ...... less than 5mW/cm2. • Leakage for a fully assembled oven with door normally closed ...... less than 2mW/cm 2 (1mW/cm 2 for Canada). • Leakage for a fully assembled oven [Before the latch switch (primary) is interrupted] while pulling the door ...... less than 2mW/cm 2. 1. Pour 275 ± 15cc (9ozss± 1/2oz) of 20°C ± 5°C (68° ± 9°F) water in a beaker which is graduated to 600cc, and place in the center of the oven. 2. Set the radiation monitor to 2450MHz and use it following the manufacturer´s recommended test procedure to assure correct results. 3. When measuring the leakage, always use the 2 inch (5cm) spacer supplied with the probe. 4. Tap the start pad or set the timer and with the magnetron oscillating, measure the leakage by holding the probe perpendicular to the surface being measured.


At least once a year, have the radiation monitor checked for calibration by its manufacturer.