Who's Online
There currently are 5576 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
;
let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
;
I had been looking for a Manual for my CS2150 for quite a while -- in fact I had just about given up. I saw this site and decided to download the Manual. When I Received it by Email I was really pleased with what I got, with the result that My Kenwood 'Scope is now 100% repaired and working well. As an AV Serviceman, you need a good 'scope, and thanks to this site, and the Service Manual, I have been able to repair it. The Manual was a copy of the Factory Original and the copy was very clear, especially in the area of the Circuit Schematics, where You really need to be sure of what You are looking at.
;
I recently purchased a manual for a Samsung DLP tv to help with a trouble shooting problem I was having. Every tv repair shop wanted close to $400.00 for the fix, but after I found Owner-Manuals.com I hit pay dirt. The manual they had for me to purchase and download was a complete service manual for the exact tv I needed. It was complete with wiring diagrams, schematics, and even part numbers. If your the fix it yourself type I highly recommend trying to find any manual here before paying someone else to fix whatever problem your having.
How to solve the problem indicated by the Error Indication of LED
(All symptom is that Lamp turns off or Lamp does not light up) Note: Before performing the troubleshooting, confirm that all connector cables in the unit are connected to connectors correctly. Error No.
1)
Problem
Cooling Fan (Fan1, Fan2 and/or Fan3) malfunction. NO
Possible Solution
Replace the Power C.B.A.Still NG, replace the Projection Unit. Still NG, replace the Main C.B.A. Replace the Projection Unit. Replace the Projection Unit. Only the Fan3 stops. Replace the Fan3.
Are the Fan1, Fan2 and Fan3 operating?
Only the Fan1 stops. Only the Fan2 stops.
2)
Mis-installed the Lamp Cover (the Lamp cover is open).
1. Tighten the screw of the Lamp Cover. 2. If still NG, replace the Cover SW (SW2911) on the Cover Switch C.B.A. 3. If still NG, replace the Main C.B.A. 4. If still NG, replace the Projection Unit. Remove P2303 connector on the LCD Drive C.B.A. and check if the resistance between pin1 and pin2 of P2811 on the Thermistor 1 C.B.A. is 5k 200k . If NG, replace the Temperature Sensor (R2811) on the Thermistor 1 C.B.A. Still NG, replace the Projection Unit. Still NG, replace the Main C.B.A. Note: The Projection Unit includes LCD Drive C.B.A.
3)
The temperature sensor (R2811) on the Thermistor 1 C.B.A. on the Fan 1 is short or open.
4)
It indicates when the temperature detected by the Temperature Sensor (R2811) on Thermistor 1 C.B.A. exceeds 55 °C (131 °F). 1. The surrounding temperature of the place of use may be too high. 2. The vents on the rear may be blocked.
1. Relocate the unit to a proper location. � Do not place in direct sunlight and other sources of direct heat. � Do not place the unit in humid or dusty location, or areas exposed to smokeor steam. (surrounding temperature should be between 0 °C (32 °F) and 40 °C (104 °F) and humidity should be between 20 % and 80 % (with no condensation).) � The vents are not blocked. It is recommended that a gap of at least 10 cm is left all around the unit even when it is placed inside a cabinet or between shelves. 2. Check if the fans are operating properly.
5)
1. 2. 3. 4.
The Lamp is not cooled off. 1. Confirm that the Thermal Fuse Unit (115�C(239�F)) on the Lamp House is not open. Thermal Fuse Unit (115�C (239�F)) is defective (open). 2. Wait until the Lamp is cooled off and try to turn the power back on. If same error LED The Lamp is defective (crack). indication continues, remove the Lamp and visually inspect it. If it is cracked, it must be The Lamp voltage becomes more over 130V or less replaced. If the Lamp is not cracked, replace the Ballast C.B.A. than 30V. 3. If still NG, replace the Main C.B.A. 5. The Ballast C.B.A. is defective. 6. The Main C.B.A. is defective. The Lamp is defective (short of the Lamp). Thermal fuse (F1302) 117 °C (243 °F) on the Ballast C.B.A. is open due to abnormal temperature rise. The Ballast C.B.A. is defective. +30V line on the Main C.B.A. error. Replace the Lamp. Replace the Ballast C.B.A. If the Lamp does not light up after attempting turning on the power 2 or 3 times, replace the Ballast C.B.A. 1. Replace the Power C.B.A. 2. If still NG, replace the Main C.B.A. 3. If still NG, replace the Tuner C.B.A. 1. Replace the Power C.B.A. 2. If still NG, replace the Main C.B.A. 3. If still NG, replace the Rear Jack C.B.A. 4. If still NG, replace the Projection Unit. 1. Replace the Power C.B.A. 2. If still NG, replace the Main C.B.A. 3. If still NG, replace the Rear Jack C.B.A. 4. If still NG, replace the Tuner C.B.A. 5. If still NG, replace the Projection Unit. 1. Replace the Power C.B.A. 2. If still NG, replace the Main C.B.A. 1. Replace the Power C.B.A. 2. If still NG, replace the Main C.B.A. 1. Replace the Power C.B.A. 2. If still NG, replace the Main C.B.A. Remove P2304 connector on the LCD Drive C.B.A. and check if the resistance between pin1 and pin2 of P2821 on the Thermistor 2 C.B.A. is 5k 1M . If NG, replace the Temperature Sensor (R2821) on the Thermistor 2 C.B.A. Still NG, replace the Projection Unit. Still NG, replace the Main C.B.A. Note: The Projection Unit includes LCD Drive C.B.A. 1. Relocate the unit to a proper location. � Do not place in direct sunlight and other sources of direct heat. � Do not place the unit in humid or dusty location, or areas exposed to smokeor steam. (surrounding temperature should be between 0 °C (32 °F) and 40 °C (104 °F) and humidity should be between 20 % and 80 % (with no condensation).) � The vents are not blocked. It is recommended that a gap of at least 10 cm is left all around the unit even when it is placed inside a cabinet or between shelves. 2. Check if the fans are operating properly. 1. Cleaning the Air Filter on the Projection Unit. 2. If still NG, replace the Projection Unit. 3. If still NG, replace the Main C.B.A.
6) 7) 8) 9)
10)
+9V line on the Main C.B.A. error.
11)
+5V line on the Main C.B.A. error.
12) 13) 14) 15)
+3.3V line on the Main C.B.A. error. -5V line on the Main C.B.A. error. +6V line on the Main C.B.A. error. The temperature sensor (R2821) on the Thermistor 2 C.B.A. on the Lamp House is short or open.
16)
It indicates when the temperature detected by the Temperature Sensor (R2821) on Thermistor 2 C.B.A. exceeds 85 °C (185 °F). 1. The surrounding temperature of the place of use may be too high. 2. The vents on the rear may be blocked.
17)
Clogged air filter of the Fan Case Unit.
|
|
|
> |
|