|
Who's Online
There currently are 5557 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Great Manual. This manual is available no where else. It was exactly what I was looking for. Only in German.
;
This GRUNDIG UV5A Owner Manual is not only an instruction manual but a total functional circuit description of the Multimeter and includes circuit diagram at the end pages. It is very helpful for repairing and calibrating the instrument. It is written in two languages English and German for international support. It was very easy to repair my unit with this document. Regards, Regis Pauly, Electrical Engineer.
;
The owner's manual was evetything I thought it would be. I was able to print it out using both sides of the paper in quick order, saving me a search online for a used one.
;
Хорошее качество сканирования.
Мануал пришел часов эдак через 12. В целом доволен.
;
Fantastic quality and impressive delivery time. Based on this manual, I recommend this service without hesitation! Five Stars for certain.
Recording
Store �les in 4 folders (A, B, C and D). Each folder holds up to 99 �les.
VOL STOP REC
1 Press [$FOLDER/%MENU] to select
Built-in microphone
the folder.
Recording indicator External microphone jack [MIC (PLUG IN POWER)] Each time you press the button:
HQ
A
)B )C )D ^_____----------n
B
MICROPHONE
2 Press [REC MODE] to change the recording quality.
0
Each time you press the button:
50 100
HQ
P REC VOL
) SP ) LP ^_____-----n Recording quality HQ (High quality) SP (Standard play) LP (Long play)
HQ
Available recording time
B
HOLD
Release HOLD before operation
FOLDER/ MENU
33 minutes 65 minutes 210 minutes
REC MODE
�Use HQ or SP if the sound source is far away.
ERASE
H L
You can also change the microphone sensitivity and VAS setting. (See below)
3 Press [REC] to start recording.
The recording indicator lights. Each time you press [$FOLDER/%MENU]: Recording time Recording level Available recording time File number �Available recording time also Recording time appears when the remaining time becomes very short.
B
0�����50����100� 0�����50����100�
STO
MIC SENSE
HQ
HQ
,.
M S
B
,.
H
H
M
S
Available recording time
� Recording through the external microphone
The built-in microphone switches off.
RR-QR153
4 Press [STOP] (or [�]) to stop recording.
Information for the �le appears one after the other: Remaining memory
HQ
0�����50����100� 0�����50����100�
Connect the included microphone to the [MIC] jack.
RR-QR150
HQ
HQ
HQ
HQ
Use a condenser microphone without a built-in power supply. Plug type: 3.5 mm (1�8 in.) monaural
B
REC DATE
PM M D
B
REC DATE
B
B
B
PM H M S
Date
Time
Recording time
No. of �les
Clock
Changing microphone sensitivity
H
MICROPHONE
Timer recording
Preparation: Select the folder and recording quality (Steps 1 and 2 above). 1 While stopped, press and hold [$FOLDER/%MENU] until the display changes. Do each of the following within 10 seconds 2 Press [$FOLDER/%MENU] until �RECF� appears. 3 Press [:,9] to select �On�. 4 Press [1]. 5 Set the times.
1 2 3 4 Press [:,9] to change the start time. Press [1]. Press [:,9] to change the end time. Press [1].
L
0 50 100
H (High): Relatively soft sounds are recorded.
FOLDER/ MENU
REC MODE
H L
L (Low): Only relatively louder sounds are recorded. Use when recording close
ERASE
MIC SENSE
H L
to the mouth.
Preventing unnecessary recording (VAS: Voice activated system)
VAS detects silence and pauses recording automatically. It is especially effective when microphone sensitivity is set to L.
MIC SENSE
1 While stopped, press and hold [$FOLDER/%MENU] until the display changes. Do each of the following within 10 seconds 2 Press [$FOLDER/%MENU] until � � appears. 3 Press [:,9] to select �On�. 4 Press [1].
� � and recording indicator �ash while VAS is waiting for a sound to record.
When �nished, the display changes in the following order: ON time # OFF time # Current number of �les # Clock �RECF� �ashes during recording and goes out when �nished. (The setting is also canceled.)
� To check the timer settings:
1 While stopped, press and hold [$FOLDER/%MENU] until the display changes. 2 Within 10 seconds, press [$FOLDER/%MENU] until �RECF� appears.
� To cancel the timer:
Select �OFF� in step 3. �Start from the beginning again if the display returns to the clock partway through. �Press [STOP] or [�] to stop partway through.
� To turn the function off:
Select �OFF� in step 3. �Start from the beginning again if the display returns to the clock partway through. �Press [STOP] or [�] to stop partway through.
4
5
|
|
|
> |
|