Who's Online
There currently are 5891 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Great tape deck manual!
I'm very positively surprised, because it is a very long manual, lot of pages, drawings, diagrams, description of how to make the alignment and adjustment procedures.
It is as good as the old "Naka" manuals from the 1970's - if somebody have seen them, they know what I mean by that.
I recommend to buy this very much !
;
I am a vintage hifi collector. No way to fix that device without the appropriate service manual...thanks to your site I got it and every thing is easier now. I got the manual right after ordering: fast cheap accurate ... thank you
;
Wonderful job clear. Qick fantastic. These people are really good. If even a problem arise they are wonderful assisting you. These scheme is so net despite this is a very old TV. Thank you for everything!!!!!!!!
;
Detailed schematic diagram, manual for professionals
;
Good service manual,exploded view,adjusment and test point locations,head alignment,mechanical checks and adjusments,all perfect.
file:///E:/aa/UM/ALL/TH-50PHD30BX/SVC/s0102000000.html
1.2 Touch-Current Check
TOP PREVIOUS NEXT 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check. 2. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground such as a water pipe, as shown in Figure 1. 3. Use Leakage Current Tester (Simpson 228 or equivalent) to measure the potential across the measuring network. 4. Check each exposed metallic part, and measure the voltage at each point. 5. Reserve the AC plug in the AC outlet and repeat each of the above measure. 6. The potential at any point (TOUGH CURRENT) expressed as voltage U1 and U2, does not exceed the following values: For a. c.: U1 = 35 V (peak) and U2 = 0.35 V (peak); For d. c.: U1 = 1.0 V, Note: The limit value of U2 = 0.35 V (peak) for a. c. and U1 = 1.0 V for d. c. correspond to the values 0.7 mA (peak) a. c. and 2.0 mA d. c. The limit value U1 = 35 V (peak) for a. c. correspond to the value 70 mA (peak) a. c. for frequencies greater than 100 kHz. 7. In case a measurement is out of the limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to the customer.
Figure 1. Measuring network for TOUCH CURRENTS